iBoot-G2S

iBoot Web Power Switch

iBoot-G2S

iBoot-G2S

Regular price $279.00 USD
Regular price Sale price $279.00 USD
Sale Sold out

In stock (can be backordered)

SKU: 1410046

Model iBoot-G2S has a built-in 10/100 network switch that makes installation in those hard to reach locations a breeze. No need for a separate cable run or router port to get the cost savings of remote reboot. Perfect for kiosks, media players or wherever a dedicated router port is hard to come by. iBoot will save you time and money by reducing costly downtime. Just point your browser to the iBoot, login and you are one click away from bringing that failed system back to life. iBoot will even detect failed systems and take immediate action.


View full details

Major Project Expertise

If you manage a network with hundreds or thousands of sites, every second of downtime costs you serious amounts of dollars. Our solutions are optimized to help you deploy and manage large scale installations around the world and keep them running with minimal downtime.

TOP FEATURES
  • Simple Web Control
  • iBoot-G2S Built-in 10/100 Switch
  • Free Cloud Service
  • iBoot Automatic Reboot
  • iBoot Expansion
  • UL Listed for Safety

iboot web power switch

iBoot-G2 Status Page

Clean web page design makes it easy to see the status and control power to any outlet. History log shows the last 5 events.

Adaptive mobile pages make it easy to make that quick reboot from you smartphone while on the go.

2 port Network switch

Simplify Wiring and Installation Costs

Perfect for Existing Installations

Get the reboot you need without an unnecessary cable run to the wiring closet. With Model iBoot-G2S, the built-in 10/100 switch makes it easy to add the power of iBoot to your existing installation. Perfect for digial signage, kiosks and telemetry systems in those hard to reach areas. Putting the iBoot in-line between the router and the server makes it easy to test both and reboot automatically.

Iboot cloud service

Single Sign-On for iBoots Worldwide

iBoot Cloud Service (iBCS) allows customers with iBoot to access and control multiple iBoots in multiple locations from a single portal with a single sign-on.

iBCS will not only make using iBoots easier, by consolidating all units into one sign-on and interface, it will also enhance the number of situations where iBoot can be deployed.

  • Customers with Dynamic IP addressing to always be able to access their iBoot from any location.
  • Service providers manage multiple customer accounts with diverse security configurations
  • Customers that do not allow in-bound connections to access their iBoots.

Read More about iBoot Cloud Service

Download the setup guide

Visit the iBoot Cloud Service Site


Autoping router test

Iboot POE

The fastest way to get back on-line

AutoPing
iBoot automatically monitors and protects your network. AutoPing continuously tests your connectivity to the internet or to any device on your network. When the network is down, or the device stops functioning, iBoot reboots the failed system to get you back on-line fast.

For servers, the Heartbeat service generates a “I’M OK” message from your server to iBoot. When that message dissapears, iBoot will reboot the server, using Graceful Shutdown if possible prior to using power off to reboot the crashed system.

Scheduling

With iBoot’s real time scheduler, you can use regular reboots to insure a fresh start each day. Power Up and Down equipment as needed to minimze energy consumption, heat and extend product life. Turn off equipment automatically when not needed for security and access control.

 

 2 port Network Switch

Digital inputs and outputs

iBoot-G2S and iBoot-G2+ are expandable with low cost satellite units to provide independent control of up to three outlets, with separate AutoPing monitoring as needed. If not used with the expansion units, the ports on the iBoot-G2S can be used as General Purpose I/O or as manual override control for the power outlets.

iBoot-G2+ and -G2S Expansion ports can be used to connect to manual switches or alarm relays for local outlet control. The digital outputs can be use to control external equipment, like a notificaion lamp or as input to an alarm panel.

Culus Listed 

 

Protect Your Users and Comply with OSHA

Dataprobe Remote Reboot products are UL Listed. This means they are tested by Underwriters Labratories and Certified to meet their exacting standards. It also means that the tests conducted are appropriate for the type of device under test. Only devices that are tested and pass all the tests conducted by UL can apply the UL label.

Dataprobe PDUs are listed under UL 60950-1, and as such are designed for stricter data center environments. Only UL 60950-1 insures that PDUs offer appropriate branch circuit protection.

Other companies use independent labs that test to UL standards. These may or may not be the appropriate safety standards. It is very easy to say tested to UL standards, but that might be for noise emissions or something other than fire safety. Some companies completely forgo safety testing!

Don’t get in the car just to push that big red button. iBoot can automatically restart crashed systems or put the power of remote reboot in your hands, wherever you are.

How Much Can You Save?

Discover your true Cost of Downtime and how fast your ROI on iBoot will be.

Learn More about iBoot-G2S

Features of iBoot-G2S

Web Browser Power Control

Clean Web page design for immediate status and power control. Auto detects mobile browsers. No special software required.

Built-In 2 Port 10/100 Switch

Eliminate extra cable runs and make installation a snap. Add iBoot to an existing Kiosk or Sign Install without having to add an additional switch and power supply.

Automatic System Restoral

AutoPing and Heartbeat detect network or equipment outage and takes immediate action to restore your network or device. Real time scheduling to have a fresh reboot each morning or minimize power waste at night.

Cloud Control

Manage all your iBoots from a single sign-on. Control power worldwide from any web browser, anytime anywhere.

Graceful Shutdown

Attempts to do a Graceful Shutdown or Restart on Windows platforms prior to hard power switch.

Expandable

Add one or two iBoot-EXP expansion units with independent control, and AutoPing. When not used for expansion units, the inputs and outputs can be used for general purpose I/O or as manual power control.

USB Port

Out-of-band management with simple serial commands for status, control and setup.

UL Listed

We take your safety seriously. Be confident to pass fire marshal and OSHA inspections.

Dual Password Protected

Separate user and administrator passwords. Deploy iBoots throughout your organization.

IP Addressed, 10/100 Base-T

Use on any Ethernet IP network. Public or private. Supports DHCP and alternate ports for Web Access.

Direct TCP and Software Control

Control iBoot-G2S directly from your software application for the highest degree of power control integration. Simple protocol is freely available. Use iBoot-G2S control program to call power control from any network management system.

110/220 VAC Operation

Auto ranging power input. Deploy iBoot-G2S anywhere in the world. iBoot-G2S uses IEC320 Connectors and includes line and extension cords for North America.

12 Amp Switching

Current for most Servers, Routers, Kiosks, etc. 10 Amps at 220 VAC.

Screenshots of iBoot-G2S

Enlarge

Enlarge iBoot-G2S Status with AutoPing Enabled

Clean web page design makes it easy to see the status and control power to any outlet. History log shows the last 5 events. If AutoPing or Heartbeat are enables, their status is displayed as well.

Enlarge

Scheduling Setup

All the setup is handled with easy web forms. Set multiple schedules to have a clean reboot every morning, or shut down at night to reduce power waste.

Enlarge

Mobile Pages

Take power control with you wherever you travel. iBoot Automatically detects mobile browsers and provides reduced clutter for easy one thumb access.

Specifications of iBoot-G2S

Power

12 Amps at 105-125 VAC, 10 Amps at 210-240 VAC


Power Switching

12 Amps at 105-125 VAC, 10 Amps at 210-240 VAC

Power Connectors

Power Inlet: IEC 320 C13 Plug. Line cord for North America Included. 16AWGX3C x 6’/2m Power Out: IEC 320 C14 Receptacle. Extension Cord for N. America Included. 16AWGX3C x 2’/60cm


Network

10/100base-T, Auto sensing Uplink/Downlink Cat 5 Cable Included 6’/2m long

USB Mini-B Com Port 9600 8 N 1

Protocols

IP Addressable. DHCP or Static HTTP Web Server built-in, Port Assignable Telnet Server built-in, Port Assignable DxP Messaging Protocol, Port Assignable Auto-Ping TCP Protocol Heartbeat Detector Protocol

External I/O

Two Inputs, Two Outputs, Screw Terminal Connections:

DesignatorNameDescription
V+
Power Out
This is +12 VDC power out from the iBoot-G2+ Maximum current 100 mA
IInput
Input for status signals. Dry Contact input or Open Collector.
GGround
Signal Ground for Input and Output
OOutput
2N3904 NPN Transistor. 100 mA Maximum

Browser

Form Processing Browser Required Mozilla 3.0 or IE 3.0 or greater

Security

Dual Password Protected, User and Admin

Physical

H x W x D: 2.0″ x 3.2″ x 4.2″ (60mm x 82mm x 107mm) Operating Temperature 0 to 50 Deg. C

Reliability

MTBF 320,000 Hours Operating Cycles 10,000,000 Mechanical. 100,000 at Maximum Load

Compliance

RoHS/WEEE FCC Part 15 Class B AC Versions UL/cUL UL60950 Listed I.T.E File No. E225914 CE Directives 89/336/EEC, 92/31/EEC and 93/68/EEC